Show/Hide Toolbars

MESYS Calculation Software

The result overview shows the reference life L10r in 106 rotations and the reference life L10rh in hours. The modified reference life Lnmr considering reliability and lubrication is also shown in 106 rotations and in hours.

The maximum pressure and the static safety provide information about the maximum loading.

all_img406

 

The result overview can be customized using “Extras->Result overview”. The items shown in the overview can be selected and additional items can be added using the all_img70-button or the context menu with the right mouse button. Note that only values are actually shown in the result overview that are valid. So you will see fewer values than selected in the settings.

The settings for the result overview are saved in the windows user profile not in the calculation file. So they will be the same for different calculations.