The general calculation approach and settings are defined in this tab.

The individual fields are described in the following text.
In the tab "General", the "Project name" and a "Calculation description" can be added. They are added to the report for information. Further settings are:
•Flag "Consider load spectrum": Flag active: The tab "Load spectrum" for definition of a load spectrum is activated and input of a load spectrum is enabled. Nominal load input in tab "Geometry" is removed. Flag inactive: Calculation is with a nominal load only.
•Flag "Use diametral pitch instead of module": Flag active: Input of gear geometry is based on diametral pitch instead of normal module. Flag inactive: Input of gear geometry is based on normal module instead of diametral pitch.
•Flag "Calculate root stress based on FEA": Flag active: In addition to the strength rating as per the calculation method, the tooth root stress level is calculated using finite element analysis. For helical gears, the calculation is done in the normal section. Flag inactive: The strength rating is done as per the calculation method only and no finite element analysis is done.
•Flag "FEA root stress based on virtual spur gear": Flag active: The finite element analysis is done on the virtual spur gear instead of on the normal section. Flag inactive: The finite element analysis is done on the normal section instead of at the virtual spur gear.
•Flag "Continue on geometry errors": Flag active: The calculation will not stop on geometry errors. Some results may be invalid. Flag inactive: The calculation will stop on geometry errors.
•Value "Minimum tooth thickness factor san,min": The topland width or tooth thickness at tip diameter, divided by the normal module is compared to this value. If it is equal or smaller, a warning is issued.
•Value "Minimum distance between planets dPl": The distance between the tip diameter of the planets is calculated and compared to this value. If it is equal or smaller, a warning is issued.
•List "Geometry for strength calculation": Several options are available for the geometry within the tolerance field used in the strength calculation along ISO 6336. to be considered within the tolerance field. ISO/TR 6336-30 claims it uses nominal dimension with minimal tooth thickness for factors YS and YF, but this does not fit to all examples in the report. In case of large tolerance fields either the average position in the tolerance field or the minimum tooth thickness should be used. The minimal tooth thickness will be the critical one for bending strength. For the contact ratio either the maximum or the minimum could be the critical one, dependent on the actual application. To be in line with ISO 6336, use list item "Nominal with minimal tooth thickness for YF/YS".
•List "Thermal expansion": The thermal expansion of the gears and the housing can be considered for the calculation of contact ratios
oList item "is not considered": No effect of temperature, input fields are hidden, see below screen shots.
oList item "is considered on one limit only": Only the limit that is unfavorable is shifted. If the upper thermal shift is negative, it is set to zero. If the lower thermal shift is positive, it is set to zero. As a result, the resulting tolerance field becomes larger, since the original, temperature independent tolerance field remains contained within it. This is not the case when both limits are considered, see below.
oList item "is considered on both limits": The upper and lower center distance allowances are both shifted by the same amount based on the thermal expansion. The tolerance band width does not change, only its position changes.
oNote that the reference temperature is 20°C.